상완혈 자침시 복부 장기의 안전성 확보를 위한 초음파시스템의 신뢰도 측정
Reliability Measurement of the Ultrasound for Safety of the Abdominal Organs on Acupuncturing Sangwan (CV13)
0
조회
0
다운로드
6
인용
0
참고문헌
키워드
초록
Objectives The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver Methods We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with a ultrasound device with three methods of 3.5 MHz convex probe and gel, 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad, three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver were 9.20 (9 MHz linear probe and gel), 14.70 (9 MHz linear probe and solid gel pad). So we concluded that repeatabilities and reproducibilities of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with the methods of 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad were acceptable.
Abstract
Objectives The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver Methods We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with a ultrasound device with three methods of 3.5 MHz convex probe and gel, 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad, three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver were 9.20 (9 MHz linear probe and gel), 14.70 (9 MHz linear probe and solid gel pad). So we concluded that repeatabilities and reproducibilities of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with the methods of 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad were acceptable.
참고문헌 (12)
- Lou XF, "Study on angle and depth of needle insertionin acupuncture at Zusanli (ST36)", Zhongguo Zhen Jiu, 26, pp.483~486 (2006)
- Li YD, "Study on needlingdepth of Dazhui (GV14), Jianzhongshu (SI15),Xuanshu (GV5) and Mingmen (GV4) with CT", Zhongguo Zhen Jiu, 25, pp.863~864 (2005)
- Yang SD, "Study on needling depth of Fengfu (GV16) withCT", Zhongguo Zhen Jiu, 28, pp.47~48 (2008)
- Lin JG, "Studies of needling depth in acupuncturetreatment", Chin Med J (Engl), 110, pp.154~156 (1997)
- Chen HN, "Safedepth of abdominal acupoints in pediatric patients", Complement Ther Med, 16, pp.331~335 (2008)
- Chen HN, "The therapeutic depth of abdominal acupuncturepoints approaches the safe depth inoverweight and in older children", J AlternComplement Med, 15, pp.1033~1037 (2009)
- 심찬섭, "복부초음파 진단학", pp.9~10 (2000), 여문각
- 송한덕, "초음파진단의 이해", pp.4~ (2000), 군자출판사
- 전국한의과대학, "침구․경혈학교실. 침구학 上", pp.732~733 (1994), 집문당
- 전국한의과대학, "대학경락경혈학각론 下", pp.1179~1181 (2009), 의방출판사
- 이승훈, "Minitab 측정시스템 분석", pp.53~62 (2006), 이레테크
- Bland JM, "Statistical methods forassessing agreement between two methods ofmeasurement", Lancet, 1, pp.307~310 (1986)