자성홀소자를 이용한 집게형 맥진기의 유효성 평가를 위한 허맥과 실맥 로지스틱 회귀식 탐색
Investigation of Logisitic Regression Equation of Vacuous Pulse and Replete Pulse for Efficacy Evaluation of Clip-type Pulsimeter by using Magnetic Hall Device
1
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
The aims of this study are to investigate a logisitic regression equation of the vacuous pulse and the replete pulse for efficacy evaluation of clip-type pulsimeter by using magnetic Hall device. To evaluate the efficacy of clip-type pulsimeter by using magnetic Hall device as sensing the minute movement of a radial artery, one research clinical trial have been performed. The number of subject was 120, the clinical data of patients did treated with a normal statistical method. The systolic peak amplitude, the reflective peak amplitude and time,and the notch peak amplitude and time are analyzed major efficacy parameters to discern the vacuous pulse and the replete pulse. The equations included of five parameters such as systolic peak amplitude, the reflective peak amplitude and time, and the notch peak amplitude and notch amplitude time for determination of the vacuous pulse and the replete pulse were deducted by statistical logistic regression method. It suggests that the logistic regression equations are possible to develop the oriental algorithm for pulse diagnosis.
Abstract
The aims of this study are to investigate a logisitic regression equation of the vacuous pulse and the replete pulse for efficacy evaluation of clip-type pulsimeter by using magnetic Hall device. To evaluate the efficacy of clip-type pulsimeter by using magnetic Hall device as sensing the minute movement of a radial artery, one research clinical trial have been performed. The number of subject was 120, the clinical data of patients did treated with a normal statistical method. The systolic peak amplitude, the reflective peak amplitude and time,and the notch peak amplitude and time are analyzed major efficacy parameters to discern the vacuous pulse and the replete pulse. The equations included of five parameters such as systolic peak amplitude, the reflective peak amplitude and time, and the notch peak amplitude and notch amplitude time for determination of the vacuous pulse and the replete pulse were deducted by statistical logistic regression method. It suggests that the logistic regression equations are possible to develop the oriental algorithm for pulse diagnosis.
참고문헌 (10)
- Nam DH, "Measurement of spatial pulse wave velocity by using clip-type pulsimeter equipped with Hall sensor and photoplethysmography", Sensor, 13, pp.4714~4723 (2013)
- Xu L, "Objectifying researches on traditional Chinese pulse diagnosis", Informatica Medica Slovenica, 8, pp.56~63 (2003)
- Chiu YC, "Determination of pulse wave velocities with computerized algorithms", American Heart Journal, 121, pp.1460~1469 (1991)
- Tyan CC, "A novel noninvasive measurement technique for analyzing the pressure pulse waveform of the radial artery", IEEE Trans. on Biomed. Eng, 55, pp.288~297 (2008)
- Fleiss JL, "Statistical methods for rates and proportions" (1981), Jonh Wiley & Sons
- Cody RP, "Applied statistics and the SAS programming Language" (2006), Pearson Prentice Hall
- 이상석, "A New Measurement Method of a Radial Pulse Wave Using Multiple Hall Array Devices", Journal of Magnetics, 14(3), pp.132~136 (2009), 한국자기학회
- Lee SS, "Measurement of blood pressure using an arterial pulsimeter equipped with a Hall device", Sensors, 11, pp.1784~1793 (2011)
- Yoshikawa H, "Clinical efficacy of Ninjin-Youei-To for recovery of reduced physical strength of the patients after prostate hypertrophy operation", J. Japan Oriental Medicine, 9, pp.617~622 (1999)
- Kim J, "Determination method of the vacuous pulse and the replete pulse. Republic of Korea Patent No. 10-2011-0137215, Date : Dec. 22th", ~ (2011)